TM 5-4120-386-14
4-24. CONTROL MODULE-Continued.
REMARKS
ACTION
LOCATION/ITEM
Repair
Remove nicks, dents or
a.
3. Control
deformation if minor.
Module
b. Prime and paint as necessary.
Cover
Remove dents or deformation if
4. Designation
a.
minor. Replace if major.
Plate
Replace if illegible.
b.
Remove dents or deformation
a.
5. Front and
if minor. Replace if major.
Back Plate
Replace if cracked.
b.
Straighten posts if bend is
6. Frame
a.
minor.
Posts
Replace if bend is major.
b.
Inspection
Turn temperature control knob
7. Temperature
a.
from stop to stop to ensure
Selector
smooth operation. Replace if
Switch
binding occurs.
b . Inspect temperature control
knob for chips, cracks, or
indicator line cannot be
readily seen. Replace if
found.
c. Inspect sensor bulb and line for
kinks, excessive bends, nicks,
breaks, or cuts. Replace if
found.
d. Inspect sensor line grommet (6)
for tears, cracks, and general
deterioration. Replace if
found or missing.
Inspect contacts. Replace switch
a.
8. Evaporator
if damaged.
Fan Speed
b. Inspect contact leads for damage
Switch
or corrosion. Clean if minor or
replace if major.
c. Inspect wiring for breaks or
damage. Replace if found.
d. Inspect switch for distinct
click when changing positions.
Replace switch if not found.