TM 5-4120-386-14
4-41. STORAGE AND SHIPMENT-Continued.
REMARKS
LOCATION/ITEM
ACTION
Shipment - Continued
Prepare unit as prescribed for
Preparation
long term storage.
Fabricate a wood shipping
a.
2. Shipping
container conforming to PPP-B-601,
Container
Domestic Type. A minimum of 1
inch clearance will exist between the
air conditioner and walls of the box.
The box will be modified with skids
located so that the bolts securing the
air conditioner pass through the
skids. Bolt heads will be countersunk
into the bottom of the skids. The
bolts with washers, should protrude
at least 3/8 inch above the skid and
not more than 1/2 inch.
b.
The air conditioner will be packed in
the shipping container and secured to
the skids with four bolts (3/8-24) and
washers.
Wood spacers will be padded with
c.
water resistant cushioning material
to prevent abrasion. Corner pads
constructed of fiberboard will be
used on all top and bottom edges of
the air conditioner.
d.
The shipping container will be closed
and secured with nails and steel
strapping material.
e.
The air conditioner will be stored and
shipped in the operating (upright)
position. The words "THIS END UP"
with arrows will be placed on each
side of the shipping container. The
letters will be black, at least 3 inches
high, and located within the upper
third of each side.
4-111/(4-112
blank)
|