TM5-4120-387-14
Figure 4-31. Time Delay Relay (K6)
(3) Extend relays and bracket from junction box, taking care not to damage
leads.
(4) Remove and tag leads from relay (K6).
(5) With screwdriver and wrench, remove the four screws and self locking
nuts on bracket.
(6) Remove relay (K6).
c.
Inspection
(1) Check relay for cracks, evidence of overheating, and any other visible
damage.
Repair if damaged.
4-85
|