TM5-4120-387-14
Figure 4-34.
Heater Relay (K2)
(2) For Model 3770, remove four screws, four locknuts, and relay,
(3) For Model 3873, remove four screws and four clips and relay assembly
from junction box,
Remove four screws and relay mounting plate from relay,
e.
Installation
(1) For Model 3770, install relay, four screws and four locknuts,
(2) For Model 3873, install four screws and relay mounting plate onto relay
and then install this relay assembly into junction box with four screws and four clips,
(3) See tags and wiring diagram (fig. 4-7) and connect wiring leads,
(4) Remove tags.
(5) Using screwdriver, secure junction box cover with
fastener screws,
Follow-on procedure: Install junction box, (See para. 4-29.)
four captive panel
4 - 9 2
Change 3
|