TM5-4120-387-14 Loosen the hose  connections  to  the  two  air  conditioner  charging  valves slightly. d. Open the two charging manifold valves. e. Open the refrigerant -22 drum value slightly to allow a small amount of refrigerant conditioner f. Close liquid refr g. Posit to purge-air from the hoses. Tighten-the  hose  connections  at  the  air charging   valves. the  low  pressure  (suction)  charging  manifold  valve.  Never  introduce igerant into the low pressure (suction) charging valve. ion the refrigerant -22 drum so that liquid will  be used for charging. (Some drums must be inverted and some are equipped ’with a selector valve.) h. Using accurate scales,   measure and record the weight of the refrigerant -22 drum. i. Open the refrigerant -22 drum valve. j. Open the high pressure charging valve on the air conditioner. Allow liquid refrigerant to enter the system until the drum weight has decreased by 2.3 pounds (1.05 kg) or until system pressure has equalized. k. Close the refrigerant drum valve  and the  high  pressure  (discharge)  manifold valve. 1. Connect air conditioner to a remote control module assembly. m. Connect  power. n. Press and release both pressure switch reset buttons. o. Turn air conditioner on and operate in the COOL mode with the Temperature control thermostat set at a maximum DECREASE position and fan speed set to  HI SPEED. p. I f     t h e     2 . 3     p o u n d     ( 1 . 0 5     k g )     f u l l     c h a r g e     w a s     o b t a i n e d ,     s k i p     s t e p s     q     t h r u     s . If the system pressure equalized prior to obtaining a full charge of 2.3 pounds (1.05 kg), proceed with step q. q. Switch the refrigerant drum to the gas only position. r. Be sure that the refrigerant drum has been switched to the gas position and open the refrigerant drum valve,   the  low  (suction)  pressure  charging  manifold valve, and the low (suction) pressure charging valve on the air conditioner. Monitor  the  weight  of  the  refrigerant  drum  as  the  air  conditioner  compressor pulls additional refrigerant gas into the system until the full 2.2 pound (1.0 kg) charge is obtained. When the system is fully charged, immediately close the air conditioner  low  pressure  charging  valve  and  the  refrigerant  drum  valve. 5-18

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business