TM5-4120-387-14
Figure 5-24. Fluid Pressure Regulating Valve
(1) Using two wrenches, remove
valve (L2).
(2) Remove data plate and coil
(3) Place coil in a supporting
nut that secures coil to plunger on solenoid
from plunger.
place as far as the leads will allow.
(4) Using screwdriver and wrench, remove screw, nut, spacer and clamp that
secure valve to casing.
(5) Using wet rags or asbestos cloth, insulate tubing and valves in the
area of the fluid pressure relief valve.
(6) Purge the system with nitrogen and debraze the tube connections. (See
paras 5-7 and 5-8.)
(7) Remove the fluid pressure regulating valve.
5-66
|