(5) Purge the system with nitrogen paras 5-7 and 5-8.) (6) Remove the receiver. c. Installation (1) Using wrench and screwdriver, lockwashers and nuts each on two receiver (2) Place the receiver on the tube TM5-4120-387-14 and debraze the tube connections. (See loosely secure receiver with two screws, clamps. ends, purge the system with nitrogen, and braze the tube joints. (See paras 5-7 and 5-8.) (3) Using a screwdriver, secure the two receiver clamps to the casing side panel  with  two  screws  and  lockwashers  each  clamp (4) Using screwdriver and wrench, tighten (5) Replace the dehydrator. (See para 5-13.) two clamps on receiver. (6) Leak test all newly connected joints and those in the repair area. (See para  5-9.) (7) Evacuate and charge the refrigerant system. (See paras 5-10 and 5-11.) Follow-on  procedure: Install junction box. (See para 4-29.) 5-69