TM5-4120-387-14 (5) Access to the front and back of the cabinet for routine operation and servicing  and  for  necessary  maintenance  actions. (6) Access to the top of the cabinet for removal of the top panel and sufficient  headroom  to  allow  maintenance  actions  and  internal  component  removal and installation through the top panel opening. (7) A source of 115 volt, single phase,    50/60 hertz input power rated at 17.3 amps. The power source outlet should be located as near as possible to the installed location of the air conditioner. The power source wiring must include a disconnect switch. However, provisions should be made to insure that power is not disconnected durinq normal operation and that the disconnect is not used to turn off the air conditioner for normal shut-down. (8) An earth ground capable of handling 17.3 amps. (9) Check that no source of dangerous or objectionable near the fresh air intake. (10) If possible make use of terrain features such as fumes   are   located trees and buildings to provide a shaded location. This will minimize the cooling load on the air condi- tioner. (11) If possible avoid locations where the condenser and fresh air intakes will be laden with dust, dirt, soot, smoke, or other debris. b. Through the wall installation. Prepare an opening in the wall large enough to slide the air conditioner through. (See fig. 4-2.) Consideration should be given to service of internal components. All  openings  around  air  conditioner  must be sealed air tight. c. Inside installation. Manufacture  an  arrangement  of  ducts  for  the  condenser intake and discharge air openings,    and the fresh air damper intake and/or CBR filter intake, if installed. Ducts may be made for attachment to the air conditioner cabinet using the mounting holes for the condenser inlet and outlet guards, and the fresh air screen and/or the air intake on the CBR filter or some other arrangement may be made. Prepare appropriate openings in an exterior wall for  the  ducts. Ducts may be designed to use the condenser inlet and outlet guards, and the fresh air screen supplied with the air conditioner and relocated and installed on the new duct work. Adequate  replacements  or  some  other arrangement of these items may be provided. Easy access to fresh or return air filters must be provided. Filters may be left in position in unit or relocated in duct work. Some installations (filters relocated in duct work) may require different size filters. 4-6

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business