4120-01-238-4277">
|
|
TM 5-4120-393-14
4-65.1. 16 Inch Adapter Duct (Model F60T-2HS Only) (cont)
Figure 4-65.1. 16 Inch Adapter Duct
INSPECTION
1.
Check that duct is not bent, cracked, or punctured.
2.
Check that gaskets and insulation are not torn, loose, or missing.
3.
Check that duct connector catches are in place and in good condition.
4.
Refer repair of panel, gaskets, catches, and insulation to Intermediate Direct Support Maintenance.
REPLACE
For damage of greater extent, replace entire duct adapter.
INSTALLATION
1.
Align mounting holes with casing fasteners.
2.
Using screwdriver, secure adapter duct (3) with twenty eight screws (1) and flat washers (2). The center top two
screws may be replaced with 10-32 x 0.75 Ig hex head screws (MS51849-66 or equal) to ease installation.
NOTE
FOLLOW ON MAINTENANCE:
Connect power.
Change 4 4-149
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |