TM 5-4130-234-13&P
c. Replace defective wire lugs.
a. Replace defective insulated wire, as required with
19 strands, AWG 18 of same color and length high
temperature insulated electrical wire. See figure 2-1 for
electrical schematic.
b. Replace defective solid wire, as required, with
5-6.
Thermocouple Gage Control (14, fig. 5-2).
AWG 18 of same length solid electrical wire.
5-3
|