TM 55-8145-221-14&P
0010 00-3
REFRIGERATED CONTAINER SYSTEM
OPERATOR TROUBLESHOOTING PROCEDURES Continued
0010 00
REFRIGERATED CONTAINER TROUBLESHOOTING Continued.
Table 1. Refrigerated Container Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Verify that temperature recorder
(1) has been wound.
Wind temperature recorder (1) with
key (2).
2.
Check for loose knurled nut (3)
securing paper chart (4) to
recorder platen.
Tighten knurled nut (3).
3.
TEMPERATURE RECORDER
DOES NOT RECORD OR
DOES NOT RECORD
PROPERLY.
3.
Check that stylus (5) is in contact
with paper chart.
If stylus (5) is bent, damaged or
defective, notify Unit Maintenance.
1
2
3
5
4
|