TM 55-8145-221-14&P
RERIGERATED CONTAINER SYSTEM
PREVENTIVE MAINTENACE CHECKS AND SERVICES (PMCS) Continued
0012 00
Table 1. Preventive Maintenance Checks and Services for Refrigeration Container System Continued
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO
BE
CHECKED
OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
0.1
a. Inspect cover for damaged or missing
latch.
b. Inspect for cracked or missing cover
glass.
7.
Before
Recorder
Thermometer
c. Inspect for loose sensing bulb
connection at bottom of recorder.
Sensing bulb
connection loose.
INTERIOR
8.
Before
0.1
Rear Doors
a. Inspect for obvious damage.
b. Check seals for damage.
Cracks and holes
affecting
serviceability.
Door seals badly
torn.
9.
Before
0.1
Light
Check for security of components.
10.
Before
0.1
Floor
a. Inspect container floor for punctures
and obvious damage.
b. Inspect floor for blocked or clogged
drains.
Drains are blocked
or clogged.
Change 1
0012 00-2
|