TM 55-8145-221-14&P
0016 00-1/2 blank
REFRIGERATED CONTAINER SYSTEM
UNIT MAINTENANCE TROUBLESHOOTING PROCEDURES
0016 00
THIS WORK PACKAGE COVERS
Refrigerated Container System
INITIAL SETUP:
Maintenance Level:
Unit
REFRIGERATED CONTAINER.
Table 1. Refrigerated Container Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
REAR DOORS WILL NOT
CLOSE
1.
Inspect for bent, broken, or
twisted door latch hardware.
1.
Replace defective parts.
2.
TEMPERATURE RECORDER
DOES NOT RECORD OR
DOES NOT RECORD
PROPERLY.
1.
Check that stylus is in contact
with paper chart.
1.
If stylus is bent, damaged or
defective, replace defective parts.
3.
TEMPERATURE INSIDE
CONTAINER WILL NOT
STABILIZE.
1.
Inspect rear doors for damaged
or missing seals.
1.
If doors are damaged or defective,
replace defective parts.
REFRIGERATION UNIT TROUBLESHOOTING.
For Refrigeration Unit Troubleshooting Procedures, refer to TM 9-4110-258-13.
GENERATOR SET TROUBLESHOOTING.
For Generator Set Unit Troubleshooting Procedures, refer to TM 9-6115-642-10.