TM 55-8145-221-14&P
0020 00-2
EXHAUST PIPE REPLACEMENT Continued
0020 00
INSTALLATION Continued.
CAUTION
When the generator set is returned to the stowed position, fuel hose and power cable must
kept clear of slides. Fuel hose and power could be damaged if pinched by slide.
4.
Using two personnel, release retention latches (11) simultaneously, carefully push generator set (13) back into the
stowed position until retention latches lock.
5.
Install vertical exhaust pipe (9) and secure with three U-Clamps (8) and six nuts and lock washers (7). Bottom of
exhaust pipe should be ¼ inch above horizontal exhaust pipe (19).
6.
Install rain cap (6) and tighten nut (5).
7.
Install vertical exhaust shield (4) with nine flat washers (3), lock washers (2) (Item 27, WP 0081 00), and screws (1).
8.
Horizontal exhaust pipe must be able to clear through the vertical exhaust shield (4). If it does not, loosen nuts (14)
and U-Clamp (15) and push pipe down and secure by tightening nuts (14).
|