TM 55-8145-221-14&P
0027 00-5
Change 1
RECORDING THERMOMETER ELEMENT REPLACEMENT Continued
0027 00
INSTALLATION - Continued.
CAUTION
To prevent damage to thermometer, do not bend or kink element tubing
3. From outside of container, install top two clamps (5) on tube (1) and secure to wall (3) with drive rivets (6) (Item 17, WP
0081 00).
4. Carefully uncoil enough tubing to allow thermometer element (7) to be attached to bottom of recording thermometer (8).
5. Install thermometer (7) on recording thermometer (8) and secure with two screws (9).
6. Install remaining bottom clamp (5) on tube (1) and secure to wall (3) with drive rivet (6) (Item 17, WP 0081 00), with
coiled tube between bottom two clamps.
7. Install two tie-down straps (10) (Item 20, WP 0078 00) on coiled tube (1).
8. From outside of container, install one grommet (11) (Item 7, WP 0078 00) on tube (1) and insert grommet into wall (3);
seal around grommet and tube with sealant (Item 15, WP 0078 00).
9. From inside of the container, install a second grommet (11) (Item 7, WP 0078 00) on tube (1) and insert grommet into
wall (3); seal grommet and tube with sealant (Item 15, WP 0078 00).
10. Close right door (12).
11. Adjust recorder thermometer (8) (WP 0025 00).
|