TM 55-8145-221-14&P
Change 1
0005 00-4
REFRIGERATED CONTAINER SYSTEM
CONTROLS AND INDICATORS Continued
0005 00
GENERATOR SET CONTROL PANEL (Figure 4).
The control panel contains most of the operating controls and indicators for the generator set. To access the control panel,
open the control panel access door (1).
CONTROL PANEL CONTROLS.
FUEL LEVEL INDICATOR (2).
Indicates fuel level.
PANEL LIGHTS (3).
Illuminates control panel.
COOLANT TEMP. INDICATOR (4).
Indicates engine coolant temperature.
OIL PRESSURE INDICATOR (5).
Indicates oil pressure.
EMERGENCY STOP PUSHBUTTON (6).
Shuts down generator set.
FREQUENCY METER (HERTZ) (7).
Indicates generator set output frequency.
Ammeter (PERCENT RATED CURRENT METER) (8).
Indicates generator set load current as a percent of rated current.
AM-VM TRANSFER SWITCH (9).
Allows selection of current and voltage readings between output load terminals as follows:
Switch Position
Voltage
Current
LI-L2
L1-L2
L1
(3 Phase)
L2-L3
L2-L3
L2
(3 Phase)
L3-L1
L3-L1
L3
(3 Phase)
L3-LO
L3-LO
L3
(3 Phase)
L3-L1
L3-LO
L3
(1 Phase)
L3-LO
L3-LO
L3
(1 Phase)
AC VOLTMETER (VOLTS AC) (10).
Indicates output voltage of generator set.
|