TM 55-8145-221-14&P
0006 00-1
Change 1
REFRIGERATION CONTAINER SYSTEM
OPERATION UNDER USUAL CONDITIONS
0006 00
INITIAL SETUP:
Maintenance Level
Personnel Required
Operator
Two
GENERAL.
This equipment is normally shipped assembled. The assembly paragraph provides the data and procedures for the start up
and operation of the generator set and refrigeration unit on the refrigerated container assembly.
SITING REQUIREMENTS.
No site preparation required.
PREPARATION FOR USE AND ASSEMBLY.
AUXILIARY FUEL TANK SERVICING (Figure 1).
1.
Remove fuel tank filler cap (1).
__________
WARNING
To prevent injury to personnel and damage to equipment, do not top off tank. Do not
fill fuel tank above white line marked on side of tank. Movement of refrigerated
container during transport will cause fuel to spill if tank is over filled.
CAUTION
To prevent damage to generator set, use only fuels specified in the generator set
manual (TM 9-6115-642-10).
2.
Fill fuel tank (2) to white line (3) marked on side of tank. Do not top off tank.
3.
Install fuel tank filler cap (1).
2
1
3
Figure 1. Auxiliary Fuel Tank
|