TM 55-8145-221-14&P
0007 00-9/10 blank
REFRIGERATED CONTAINER SYSTEM
OPERATION UNDER UNUSUAL CONDITIONS Continued
0007 00
OPERATION IN DUSTY OR SANDY AREAS.
1.
Refrigerated Container: keep doors closed or access area covered when open.
2.
Generator Set:
a.
If possible, provide a shelter for generator set. Use available natural barriers to shield generator set from blowing
dust or sand.
b.
Wet down dusty and sandy surface areas around generator set frequently if water is available.
c.
Keep all access doors closed, as much as possible, to prevent entry of dust and sand into housing assembly.
d.
Wipe dust and sand frequently from the generator set external surface and components. When generator set is not
operating, wash exterior surfaces frequently with clean water.
e.
Service engine air cleaner assembly frequently to compensate for intake of additional dust or sand.
f.
Drain sediment frequently from fuel filter/water separator. When servicing fuel tank, be careful to prevent dust or
sand from entering fuel tank.
g.
Change engine oil and oil filter frequently.
h.
Store oil and fuel in dust-free containers.
i.
Ensure that the generator set ground connections are free of dust and sand and connections are tight before starting
the unit.
3.
Refrigeration Unit: keep cooling coils clean and free of dust buildup.
GENERAL CLEANING AND DECONTAMINATION.
1.
Wash the exterior of the refrigerated container with any suitable detergent. Thoroughly rinse with fresh water and
allow to air dry.
NOTE
Each deck-stored container must be washed by using organization after each ocean
voyage to retard deterioration.
2.
For decontamination, procedures required by TM 743-200 and FM 3-5 shall apply.
3.
Operation while in contaminated areas: refer to FM 3-3, FM 3-4 and FM 3-5.
END OF WORK PACKAGE.
|