TM 9-4110-241-13
TO 35E9-274-1
Section II. TROUBLESHOOTING
3-2. GENERAL.
This manual cannot list all malfunctions that may occur, nor all tests or inspections and corrective actions. If a malfunction
is not listed or is not corrected by listed corrective actions, notify your supervisor. Only those checks and corrective
actions which are authorized for the operator are included.
3-3. TROUBLESHOOTING TABLE.
This table lists the common malfunctions which you may find during the operation or maintenance of the refrigerator or its
components You should perform the tests/inspections and corrective actions in the order listed.
Table 3-1. Troubleshooting
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. PILOT LIGHT FAILS TO LIGHT WHEN SWITCH INSIDE REFRIGERATOR IS ON.
Step 1.
Visually check that power cord is connected to power receptacle.
MODELS M60OPF, MA120OPFA,
MODELS MDS1600N, TKR-600C
AND AA400OPF
AND TKR-4000C
If power cord is not connected, connect power cord.
Step 2.
Refer to Unit Maintenance.
3-2 CHANGE 1
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |