TM 9-4110-241-13
TO 35E9-274-1
Section IV. TROUBLESHOOTING
4-9. TROUBLESHOOTING TABLE.
This table lists the common malfunctions which you may find during the operation or maintenance of the refrigerator or Its
components. You should perform the test/inspections and corrective actions in the order listed. This manual cannot list
all malfunctions that may occur; nor all tests and inspections or corrective actions. If a malfunction is not listed or is not
corrected by listed corrective actions, notify your supervisor. Only those checks and corrective actions which are
authorized for unit maintenance are listed.
WARNING
Disconnect power supply before doing maintenance work on the electrical system.
Table 4-2. Troubleshooting
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
LIGHT WORKS, PILOT LIGHT FAILS, WHEN SWITCH IS ON.
Step 1.
(Models M60OPF, MI 20OPFA, and AA4000F). Visually check and replace bulb if required.
Step 2.
(Models MDS1600N, TKR-600C, and TKR-4000C). Check that wire connections are connected at
switch.
Replace pilot housing assembly, if connected.
MODELS MDS1600N, TKR-600C.
AND TKR-4000C
Step 3.
(Models AA6010F, MI 200PFA, and AA4000PF).
Use an ohmmeter to check continuity of wire
between pilot light socket and receptacle.
MODELS AA600PF,
AA1200PFA,
AND AA4000PF
Step 4.
(Models M60OPF, M1200PFA, and AA4000PF).
Test pilot light socket using instructions in
Replace pilot light socket, if defective.
CHANGE 1 4-17
|