4-23. FUSES F1 AND F2 TESTING AND REPLACEMENT. - Continued
b.
Removal.
(1) Be sure power has been disconnected at the source and remove two bolts (1) and lock washers (2). Open
control panel (3). Discard lock washers.
NOTE
One each 15 amp and 30 amp fuse is used.
(2) Note location and remove two fuses (4) and (5).
NOTE
Terminal hardware is supplied with fuse block.
(3) Tag wire lead terminals (7) and remove four screws (8), lock washers (9), and wire lead terminals.
(4) Remove two screws (10) and fuse block (6).
c.
Installation.
(1) Install fuse block (6) and two screws (10).
(2) Using tags and wiring diagram (fig. 1-4), install wire lead terminals (7), four lock washers (9), and screws (8).
Remove tags.
(3) Install two fuses (4) and (5) in location noted during removal.
(4) Close control panel (3). Install two new lock washers (2) and bolts (1).
NOTE
FOLLOW-ON MAINTENANCE:
Unlatch and close control panel cover door.
Connect battery (para 4-35) and put unit back into service.