TM 9-4110-257-14
c.
Installation.
NOTE
The following procedures apply to both TD1 and TD2. Quantities given are for each
relay.
Terminal hardware is supplied with time delay relay.
(1) Install adhesive tape (12) between time delay relay (7) or (8) to mounting plate (13). Install screw (14) to
mounting plate.
(2) Install time delay relay (7) or (8), using two flat washers (11), new lock washers (10), and bolts (9).
(3) If wire lead (6) terminals were damaged, repair per paragraph 4-20.
(4) Using tags and wiring diagram (fig. 1-4), install wire leads (6), nuts (4) and screws (5). Remove tags.
(5) Close control panel (3). Install two new lock washers (2) and bolts (1).
NOTE
FOLLOW-ON MAINTENANCE:
Unlatch and close control panel cover door.
Connect battery (para 4-35) and put unit back into service.
4-65
|