TM 9-4110-257-14
(4) If no failure was indicated, install wire leads (4), lock washers (6), and nuts (5). Remove tags.
(5) Close control panel (3) and install two new lock washers (2) and bolts (1).
b.
Removal.
(1) Be sure battery has been disconnected and remove two bolts (1) and lock washers (2). Open control panel
(3). Discard lock washers.
NOTE
Terminal hardware is supplied with ammeter.
(2) Tag wire leads (4) and remove two nuts (5), lock washers (6) and wire leads.
(3) Remove two self locking nuts (8), plastic bracket (9), and ammeter (7). Discard self locking nuts.
c.
Installation.
(1) Install ammeter (7), plastic bracket (9), and two new self locking nuts (8).
NOTE
Terminal hardware is supplied with ammeter.
(2) Using tags and wiring diagram (fig. 1-4), install wire leads (4), two new lock washers (6), and nuts (5).
Remove tags.
(3) Close control panel (3). Install two new lock washers (2) and bolts (1).
NOTE
FOLLOW-ON MAINTENANCE:
Unlatch and close control panel cover door.
Connect battery (para 4-35) and put unit back into service.
4-69
|