TM 9-4110-257-14
SECTION II. DIRECT SUPPORT MAINTENANCE INSTRUCTIONS
5-2.CONTROL PANEL COVER REPAIR
This task covers:
a. Repair
INITIAL SETUP
Materials/Parts:
General Purpose Adhesive
14, Appendix E
Wiping Rag
3, Appendix E
Acetone
18, Appendix E
Methyl-Ethyl Ketone
19, Appendix E
Gaskets (2)
2, Figure F-4, Appendix F
Gasket
3, Figure F-4, Appendix F
Gasket
4, Figure F-4, Appendix F
Equipment Conditions:
Control panel cover door removed (para. 4-16).
General Safety Instructions:
WARNING
Acetone and methyl-ethyl ketone (MEK) are flammable and their vapors
can be explosive. Repeated or prolonged skin contact or inhalation of
vapors can be toxic. Use in a well ventilated area, wear gloves, and
keep away from sparks or flame.
Repair.
NOTE
Repair is limited to replacement of gasket material.
(1) Remove as much old gasket material (1), (2), or (3) as possible by pulling or scraping it away from the control panel
cover (4).
Figure 5-1. Control Panel Cover.
5-3
|