TM 9-4110-257-14
5-40. INJECTION PUMP TESTING AND REPLACEMENT. - Continued
(11) Release connecting rod (19).
(12) Position manual shut down lever (22) fully to the right (clockwise).
(13) If stud (17) was removed, install it.
(14) Install new gasket (16), cover (15), flat washer (14), and nut (13).
(15) Install three flat washers (10) and screws (9).
NOTE
The lower two cover screws use special sealing washers.
(16) Install two new washers (12) and screws (11).
CAUTION
Always use two wrenches when tightening the fuel pipe to prevent turning the nozzle or injection pump fitting.
(17) Install fuel pipe (8) and tighten two flare nuts (7). Torque flare nuts to between 11 and 18 ft-lb (15 and 25 Nm).
(18) Install new gasket (6), cover (5), and three screws (4).
(19) Install cylinder casing (3), two flat washers (2), and screws (1).
NOTE
FOLLOW-ON MAINTENANCE:
Connect battery (para 4-35) and put unit back into service.
5-92
|