TM 9-4110-257-14
Table 2-1. Operator Maintenance Checks and Services for Model F10000RD-Continued
Location
Item
Item to
Not Fully Mission
No.
Interval
Check/
Procedure
Capable if:
Service
25
Weekly
Heat Shield
Inspect for loose or missing heat shield gasket
Gaskets
and for splits or tears. If damaged or loose,
notify unit maintenance to tighten or replace it as
necessary.
26
Weekly
Housing
a.
Inspect the housing for cracks and loose
or missing hardware. If cracked, notify
direct support maintenance for repair. If
hardware is loose or missing, notify unit
maintenance to tighten or replace it as
necessary.
b.
Inspect the housing for any chipped or
missing paint and evidence of corrosion. If
paint is damaged or enclosure shows
evidence of corrosion, notify direct support
maintenance to paint it.
c.
Inspect the evaporator assembly
Debris or foreign
condensate drain plastic tubing for any
material obstructing the
debris or foreign material obstructing it.
condensate drain
Remove any debris or foreign material from
opening.
the condensate drain tubing. If tubing
cannot be cleaned, notify unit maintenance
to clean it.
d.
Inspect for secure mounting to the
Housing is loose on
refrigerator enclosure. If loose, notify unit
refrigerator enclosure.
maintenance to secure it.
e.
Inspect for missing or damaged mounting
Unit mounting bolt is
bolt assembly. If missing or damaged,
damaged or missing.
notify unit maintenance to repair or replace
it.
27
Weekly
Ammeter
Inspect ammeter for cracked or damaged cover
Cover lens damaged to
lens and cracks in case.
interfere with accurate
reading or crack in case.
28
Weekly
Fuel Gage
Inspect fuel gage for cracked or damaged cover
Cover lens damaged to
lens and cracks in case.
interfere with accurate
reading or crack in case.
2-17
|