TM 9-4110-257-14
Table 4-1. Unit Preventive Maintenance Checks and Services for Model F10000RD - Continued
Location
Item
Item to
Not Fully Mission
No.
Interval
Check/
Procedure
Capable if:
Service
20
Semi-
Lamp
Inspect the lamp assembly for cracked or missing
Wire leads are loose.
Annually
Assembly
cap, loose base, and loose wire leads. Tighten cap
if loose. If damaged, wire leads are loose, or base
is loose, test, tighten base or wire leads, or replace
as necessary (para 4-22).
21
Semi-
Hourmeter
Inspect the hourmeter for cracked or missing lens
Wire leads are loose.
Annually
or any other damage and loose or missing
mounting hardware and wire leads. If damaged
or wire leads or mounting hardware is loose,
tighten, or replace as necessary (para 4-26).
22
Semi-
Ammeter
Inspect the ammeter for cracked or missing lens Wire leads are loose.
Annually
or any other damage and loose or missing
mounting hardware and wire leads. If damaged
or wire leads or mounting hardware is loose,
tighten, or replace as necessary (para 4-27).
4-25
|