TM 9-4110-257-14
Table 4-1. Unit Preventive Maintenance Checks and Services for Model F10000RD - Continued
Location
Item
Item to
Not Fully Mission
No.
Interval
Check/
Procedure
Capable if:
Service
35
Semi-
Tubing and
Inspect the tubing and fittings for kinks,
Tubing or fittings
Annually
Fittings
restriction (crushed), or evidence of refrigerant
damaged, kinked, or
leak. If damaged or evidence of leaking found,
evidence of leak is found.
notify direct support maintenance to tighten,
repair, or replace as necessary.
36
Semi-
Sending Unit
a.
Remove five screws, lock washers and
Annually
sending unit.
b.
Inspect sending unit for cracks or breaks.
Check that the float arm moves freely and
does not bind. If damaged or float lever
binds, replace sending unit (para 4-64).
c.
Install sending unit and secure using five new
lock washers and screws.
37
Semi-
Glow Plug
a.
Remove nut, tag and remove wire lead.
Annually
b.
Remove glow plug.
c.
Inspect glow plug for damage to heater
element such as swollen/split case or cracks.
If damaged, replace glow plug.
4-29
|