TM 9-4110-257-14
Table 4-1. Unit Preventive Maintenance Checks and Services for Model F10000RD - Continued
Location
Item
Item to
Not Fully Mission
No.
Interval
Check/
Procedure
Capable if:
Service
38 -
b. Inspect fuel solenoid for damage such as
Cont
dented case or evidence of overheating. If
damaged, replace it (para 4-53).
c. Install casing, two flat washers and screws.
d. Install the evaporator coil guard (para 4-18).
e. Close the control panel (para 4-20).
f. Close both front bottom doors and both side
condenser doors.
g. Connect battery (para 4-35) and put unit back
into service.
Refrigeration
Unit Interior
NOTE
The refrigeration unit must be shut down
with the battery disconnected, both side
condenser doors and both front bottom
doors must be open, the control panel must
be open, and the evaporator coil guard must
be removed for the following annual PMCS.
39
Annually
Flywheel a. Shut down refrigeration unit (para
Flywheel is broken,
2-7) and disconnect battery (para 4-35).
cracked, or damaged.
b. Open both side condenser doors and both
front bottom doors.
c. Remove screws, flat washers, and shroud.
d. Inspect flywheel for any damage such as
cracks, broken or missing air vanes, or broken
gear teeth. Notify direct support maintenance
to replace it if damaged.
e. Install shroud, flat washers, and screws.
4-31
|