TM 9-4120-367-14
TM 07592B-14/1
INITIAL SETUP
Applicable Configurations:
All
Test Equipment:
Multimeter
Special Tools:
NOne
Materials/Parts:
Heat-shrink Tubing
Solder
Hot Air Dryer
Equipment Descriptions:
Power OFF; installed in shelter
Special Environment Conditions:
None
General Safety Instructions:
See WARNING page
References:
None
Troubleshooting References:
None
Personnel Required:
Refrigeration Specialist
Location/Item
Capacitor C1
Removal
Action
a.
b.
c
d.
e.
Disconnect power supply.
Remove evaporator section top cover.
Remove screws and pull junction box from frame.
Use care to avoid breaking the sensing line.
Tag and pull "quick disconnect terminals from rec-
tifier CR1, terminals 2 and 4.
Cut leads at terminals.
Remarks
High voltage can kill.
Sensing line connects TEM-
PERATURE SELECTOR to
sensing bulb which is located
behind return air louver.
5-7
5.3 EMI CAPACITORS C2 AND C1. This task covers removal and installation.
|