TM 9-4120-367-14
TM 07592B-14/1
Commander
US Army Adjutant General Publication Center
ATTN: AGDL-OD
2800 Eastern Blvd.
Baltimore, MD 21220
Not applicable to the Marine Corps. Refer to SL-1-3.
1.6
REPORTING EQUIPMENT IMPROVEMENT RECOMMENDATIONS (EIRS). If your air conditioner needs
improvement, let us know. Send us an EIR. You, the user, are the only who can tell us what you do not like about
your equipped. Let us know why you do not like the design. Tell us why a procedure is hard to perform. Put it on an
SF 368 (Quality Deficiency Report). Mail it to us at
Commander
US Army Aviation and Troop Command
ATTN: AMSAT-I-MDO
4300 Goodfellow Blvd.
St. Louis, MO 63120-1798. We will sead you a reply.
Marine Corps -by NAVMC Form 10772 directy to
Commander
Code 850
Marine Corps Logistics Bases
814 Radford Blvd.
Albany, GA 31704-1128
1.7
1.7.1
a.
b.
c.
1.7.2
a.
b.
c.
d.
Section Il. EQUIPMENT DESCRIPTION AND DATA
EQUIPMENT CHARACTERISTICS, CAPABILITIES AND FEATURES.
Characteristics. The Keco Air Conditioner.
Cools air to a shelter,
Heats air to a shelter, and
Ventilates or circulates air in a shelter.
Cooling capacity on COOL, BTU/hour
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18,000
Heating capacity on HIGH HEAT. BTU/hour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14,300
Heating capacity on LOW HEAT, BTU/hour. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7,500
Power Requirements:
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
230
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single
Frequency, Hertz
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50/60
Amperes, phase (maximum):
Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Watts, running (maximun):
Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5,200
Heating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4,400
1-2
Capabilities and Features of Model F18H.
Phases
|