TM 9-4120-367-14
TM 07592B-14/1
5.15 CIRCUIT BREAKER CB1. - Continued
Location/Item
Removal
Continued
Testing
Installation
Action
e.
g.
h.
Remove four screws to pull cover from control
module.
Remove four screws to separate mounting frame
assembly.
Tag and pull "quick disconnect terminals from cir-
cuit breaker.
Remove four screws (single-phase) or six screws
(3-phase) to pull circuit breaker from mounting
plate.
See table 4-3, Step 1.
a.
b.
See wiring diagram figure FO-1, FO-3, FO-5,
FO-7 or FO-9.
Push "quick disconnect terminals onto circuit
breaker.
Single Phase
Model F18H
X30A20V
NO
X29A20V
C
X1D12V
A1
X2D12V
B1
X19A12V
A2
X23A12V
B2
Three Phase
F18H-3 & F-18H-4
X57A20B
NO
X33B20B
C
X1D12A
A1
X2D12B
B1
X3D12C
C1
X20A12A
A2
X22A12B
B2
X24A12C
C2
Remarks
Wire No.
Terminal No.
Wire No.
Terminal No.
5-48
f.
|