TM 9-4120-367-14
TM 07592B-14/1
INITIAL SETUP
Applicable Configurations:
Model F18H, Single Phase
Test Equipment:
None
Special Tools:
None
Materials/Parts:
Grounding Rod
Equipment Descriptions:
Power OFF; removed from shelter
Special Environmental Conditions:
None
General Safety Instructions:
See WARNING page
References:
None
Troubleshooting References:
None
Personnel Required:
Refrigeration Specialist
Location/Item
Capacitor C4
Removal
Action
NOTE
Air conditioner will have to be removed
from installed position to replace Capacitor
C4.
Disconnect power supply.
Remove air conditioner from installed position.
Remove all three top covers.
Pry cap from capacitor.
Ground capacitor to discharge electrical charge.
Tag and pull quick disconnect terminals from capaci-
tor.
Pull capacitor from retainer.
Remarks
High voltage can kill.
Paragraph 3.5
Use grounding rod.
5.19 CAPACITOR C4 (SINGLE PHASE). This task covers removal and installation.
a.
b.
c.
d.
e.
f .
g.
5-60
|