TM 9-4120-367-14
TM 07592B-14/1
5.29 HEATER. This task covers removal, cleaning, testing and installation.
INITIAL SETUP
Applicable Configurations:
Special Environmental Conditions:
All
None
Test Equipment:
General Safety Instructions:
Multimeter
See WARNING page
Special Tools:
References:
None
None
Materials/Parts:
Troubleshooting References:
Cleaning Cloths
None
Equipment Descriptions:
Personnel Required:
Power OFF; removed from shelter
Unit Maintenance (2)
Location/Item
Action
High voltage can kill.
Allow heater to cool before handling;
severe bums can result from touching
hot heater.
a. Remove power supply.
b. Remove air conditioner from shelter.
c. Remove all three top covers.
d. Remove heater thermostat from middle cover.
e. Remove heater support.
f. Remove four screws.
g. Remove nut from top heater. Allow it to slide onto
heater terminal.
h. Pull top heater from heater bracket.
Remarks
NOTE
Model F18H has six 230-volt
heaters; Models F18H-3,
F18H-4, and MHP-20-4-08
have six 120-volt heaters.
Paragraph 3.5
Do not remove leads.
Heater lead will only allow
slight movement of heater.
5-85
Removal
|