TM 9-4120-367-14
TM 07592B-14/1
6.28 EVAPORATOR BLOWER AND MOTOR. .-Continued
Location/Item
Removal of
Motor
Motor Repair
Installation
Action
Removal of motor is same as removal of fan.
See paragraph 6.29.
a.
b.
c.
d.
e.
f.
g.
h.
i.
j.
k.
l.
m.
n.
o.
p.
q.
r.
s.
Place impeller on shaft extension.
Tighten setscrew to secure.
Place fan inlet onto face of motor.
With arrow on impeller in same direction as mo-
tor rotation arrow, place shaft extension on motor
shaft.
Place fan inlet and flange in position against
blower housing.
Secure inlet and flange to housing.
Slide housing over impeller.
Secure fan inlet to housing.
Secure fan strap to two fan inlets.
Secure four mounts to base.
Secure motor and housing to base.
Secure assembly into air conditioner.
Install three brackets.
Install condensate drain.
Connect motor power connector.
Install temperature sensing bulb.
Clean air filter.
Install air filter and louver.
Connect power supply.
Remarks
Paragraph 5.24
Paragraph 5.12
Paragraph 5.20
Paragraph 5.20
6-98
|