TM 9-4120-389-14
(6)
Tighten hardware installed in steps (4) and (5).
WARNING
Do not link copper tubing. Serious injury may result if line ruptures.
(7)
Install studs of actuator into through holes of bracket on scroll.
(8)
By hand, restrain actuator.
(9)
Secure actuator to bracket on scroll with two nuts and lockwashers.
(10)
By hand, apply force to actuator plunger to verify that actuator is in the
fully retracted position.
(11)
Fit the actuator arm to the hinge shaft and actuator.
(12)
By hand, position damper blade to fully closed position.
(13)
Using hexagonal wrench, tighten set screw on actuator arm.
Follow-on procedures:
1.
Install condenser motor (See para. 4-25).
2.
Install condenser outlet guard (See para. 4-21).
Change 1 4-91
|