b.
Removal
(1)
Remove four screws, flat washers and lock nuts that secure connector and designator plate
to junction box.
(2)
Tag and disconnect wires.
(3)
Remove connector, cover and designation plate.
c.
Inspection.
(1)
Check insulation for damage. Replace if defective.
(2)
See wiring diagram (FO-1) and continuity test individual wires. Repair or replace wires with
no continuity.
d.
Repair
(1)
See paragraph 4-36 for general wire repair instructions.
(2)
See table 4-3 (wire list) for lengths and terminals/connector information.
e.
Installation
(1)
Using tags and wiring diagram (FO-1) connect leads.
(2)
Align connector, cover and designate plate hole pattern with pattern of junction box.
(3)
Secure the connector to junction box with three screws flat washers and lock nuts. (Upper
two and lower left).
(4)
Secure cover with screw, flat washers and self locking nut.
Follow-on procedure: Install junction box (See para. 4-46).