Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: CHAPTER 2 OPERATING INSTRUCTIONS SECTION I DESCRIPTION AND USE OF OPERATOR'S CONTROLS AND INDICATORS
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM 9-4120-389-14 CHAPTER 2 OPERATING INSTRUCTIONS SECTION I DESCRIPTION AND USE OF OPERATOR'S CONTROLS AND INDICATORS 2-1.  GENERAL. The Model 3864 Air Conditioner is designed for a variety of installations and for operation under a wide range of  climatic  conditions.    It  is  also  designed  for  continuous  or  intermittent  operation  as  a  self-contained  unit  or may   be   connected   to   or   used   with   external   filtering   equipment   for   operation   under   chemical-biological- radiological  (CBR)  environmental  conditions.    Operators  must  be  aware  of  any  peculiarities  or  operational limitations for their specific installation.  See the appropriate shelter or system manual for instructions peculiar to your specific installation. 2-2.  OPERATOR'S CONTROLS. See figures 2-1 and 2-2 for a general description of the controls that an operator will normally be concerned with.  For specific operating instructions, see Sections III and IV of this chapter. 2-3.  INDICATORS. The refrigerant sight glass is the only visual indicator used on the Model 3864 Air Conditioner.  The sight glass is  a  port  or  window  through  which  the  refrigerant  condition  can  be  seen.    Liquid  refrigerant  actually  flows through  the  sight  glass  chamber  only  during  cooling  cycles  when  the  air  conditioner  is  in  operation  in  COOL mode.  The unit must be operated 15 minutes in maximum cooling prior to checking condition of refrigerant at sight  glass.    The  sight  glass  is  equipped  with  a  center  indicator  that  is  moisture  sensitive.    Dry  refrigerant  is indicated by green, it turns to chartreuse when the moisture content becomes undesirable, and to yellow when the level becomes unacceptable.  Excessive moisture in the refrigerant may damage or possibly destroy the compressor. 2-1

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business