TM 9-4120-389-14
c. Installation
(1) Apply antisieze tape (Item 13, Appendix E) to threads of plug.
(2) Screw fusible plug in place while holding adapter fitting.
(3) Replace the dehydrator (See para. 5-10).
(4) Leak test all newly connected joints and those in the repair area (See para. 5-6).
(5) Evacuate the system per para. 5-7.
(6) Charge the system per para. 5-8.
Follow-on procedure: Install top cover (See para. 4-14).
5-31
|