TM 9-4120-389-14 c. Removal WARNING All refrigerant -22 must be discharged from system before attempting removal of low pressure service valve. (1) Discharge the refrigeration system per para.  5-3. (2) Purge the system with nitrogen (See para.  5-4). (3) Debraze the valve (See para.  5-5). (4) Remove valve from tube connection. d. Installation (1) Remove valve stem from replacement valve. (2) Place replacement valve on tube connection. (3) Braze valve to tube connection.  (See para.  5-5). (4) Install stem in valve body. (5) Install cap on valve. (6) Replace dehydrator (See para.  5-10). (7) Leak test newly connected joint and the repair area (See para.  5-6). (8) Evacuate the system (See para.  5-7). (9) Charge the system (See para.  5-8). Follow-on procedure: Install top cover (See para.  4-14). 5-62