TM9-4120-423-14&P
10
EMI gasket material and regular gasketing specified for this unit are supplied with adhesive
backing.
11
Cut gasket to size. Be sure that EMI gasket corners are mitered so that good continuous edge
contact is made.
12
Be sure that surface to which gasket is to be applied is clean and free of paint and old adhesive
material.
13
Remove backing material from adhesive side and immediately press gasket in place. Be sure
that good edge-to-edge contact is made on the EMI gaskets.
INSTALLATION
1
Install blocking plate and secure with four captive screws.
2
Using a screwdriver, socket and ratchet, attach the remote control harness connector (J7) and
connector gasket to the front evaporator cover with four screws and locknuts.
3
Align the holes in the EMI gasket, radio frequency filter, and front evaporator cover.
4
Using a screwdriver, install the two bottom screws in the cover and radio frequency filter.
5
Using a screwdriver, attach the chain ends for the protective connector cap and cover when the
two top radio frequency mounting screws are installed.
6
Line up screw holes in cover and air conditioner housing.
7
Using screwdriver, install cover with eight screws.
8
Install air conditioner on shelter. (See WP0006)
END OF TASK
0025 00-4
|