1
Tag leads.
2
Using cross tip screwdriver, remove screws holding leads to relay socket terminals.
3
Remove relay from socket.
4
While holding each screw from the underside, remove two lockwashers and nuts to remove relay
socket. Remove screws.
5
Repeat above process to remove two remaining relays and relay sockets.
INSTALLATION
1
Place relay socket in box and align holes.
2
Using cross tip screwdriver, secure each relay socket to box with two screws, lockwashers and
nuts.
3
Plug relay into socket.
4
Match leads to relay socket terminals using tags, wire marking and wiring diagram.
5
Using cross-tip screwdriver, secure leads to relay socket terminals.
6
Remove tags.
7
Place cover on box and line up holes.
8
Using screwdriver, attach the cover with six screws and lockwashers. Do not over tighten, it will
cause distortion. See WP0041.
9
Install evaporator section electrical module assembly. See WP0032.
10
Install top evaporator cover. See WP0026.
0038 00-3