TM9 4120-423-14&P
REPAIR OR REPLACEMENT
NOTE
Prior to removal of old gasket material or insulation, cut the new replacement material to
size using the old item as a sample.
1
Remove as much old gasket material as possible by pulling or scraping it away from the metal
surface.
WARNING
Dry Cleaning Solvent is flammable, and its vapors can be explosive. Repeated or
prolonged skin contact or inhalation of vapors can be toxic. Use a well-ventilated area,
and keep away from sparks or flame. Use goggles, gloves, and apron when appropriate.
2
Soften and remove old adhesive and gasket residue, using dry cleaning solvent and a stiff brush.
3
Minor dents and bent edges can be straightened using common sheet metal repair procedures.
Panels that are badly dented, bent, or punctured should be replaced.
4
Should touch up or refinishing be necessary, see WP0016.
5
Use only approved replacement material as specified in Chapter 8.
6
EMI gasket material specified for this unit are supplied with adhesive backing.
7
Cut gasket to size. Be sure that EMI gasket corners are mitered so that good continuous edge
contact is made.
8
Be sure that surface to which gasket is to be applied is clean and free of paint and old adhesive
material.
9
Remove backing material from adhesive side and immediately press gasket in place. Be sure
that good edge-to-edge contact is made on the EMI gaskets.
INSTALLATION
1
Using a screwdriver, socket, and ratchet, attach the two feed through cover gaskets. Use six
screws, flat washers, and locknuts.
2
Line up the holes in the feed through cover and the air conditioner housing.
3
Using screwdriver, install cover with four screws.
4
Reconnect evaporator and condenser section assemblies. (See WP0014).
0043 00-3
|