TM9 4120-423-14&P
4
Carefully remove the left end condenser cover.
REPAIR OR REPLACEMENT
NOTE
Prior to removal of old gasket material, cut the new replacement material to size using the
old item as a sample.
1
Remove as much old gasket material as possible by pulling or scraping it away from the metal
surface.
WARNING
Dry Cleaning Solvent is flammable, and its vapors can be explosive. Repeated or
prolonged skin contact or inhalation of vapors can be toxic. Use a well-ventilated area,
and keep away from sparks or flame. Use goggles, gloves, and apron when appropriate.
2
Soften and remove old adhesive and gasket residue, using dry cleaning solvent and a stiff brush
3
To replace identification, danger, and diagram plates and lifting rings, use a drill bit slightly
smaller than the diameter of the rivet being removed.
4
Drill the rivets out and remove the old part.
5
Align holes in replacement part and cover and install new rivets.
6
Minor dents and bent edges can be straightened using common sheet metal repair procedures.
Panels that are badly dented, bent, or punctured should be replaced.
7
Should touch up or refinishing be necessary, see WP0016.
8
Use only approved replacement material as specified in Chapter 8.
9
EMI gasket material and regular gasketing specified for this unit are supplied with adhesive
backing.
10
Cut gasket to size. Be sure that EMI gasket corners are mitered so that good continuous edge
contact is made.
11
Be sure that surface to which gasket is to be applied is clean and free of paint and old adhesive
material.
12
Remove backing material from adhesive side and immediately press gasket in place. Be sure
that good edge-to-edge contact is made on the EMI gaskets.
0045 00-3
|