TM9-4120-423-14&P
REMOVAL
Varistors (RV1, RV2, and RV3) and Terminal Board (TB4)
SHRINKABLE INSULATION SLEEVING (REF)
VARISTOR (RV1)
TERMINAL LUGS (REF)
VARISTOR (RV2)
VARISTOR (RV3)
SCREW (2)
LOCK
WASHER (2)
TERMINAL BOARD
(TB4)
1
Tag and remove leads and varistors.
2
Using screwdriver, remove two screws and lockwashers and remove terminal board.
REPAIR OR REPLACEMENT
1
Cut heat shrinkable tubing to approximately one-half inch (1.27 cm) long.
2
Slip heat shrinkable tubing over leads.
3
Install terminal lugs.
4
Using heat gun, shrink tubing in place.
INSTALLATION
1
Using screwdriver, secure terminal board with two screws and lockwashers.
2
See tags, wire marking, and wiring diagram. Install leads and varistors.
3
Remove tags.
4
Install right end condenser cover. (See WP0045)
5
Connect power.
END OF TASK
0048 00-2
|