TM9 4120-423-14&P
4
Push in and turn bulb clockwise to engage mounting pins.
5
Screw lens cap in place.
TEST AND INSPECTION
1
Lamp should light in all operating modes.
2
Lamp may be tested with MODE SELECTOR SWITCH in OFF position. Push in. Lamp should
light.
3
Replace bulb if it does not light.
4
Check that lens cap is not cracked or broken, mounting hardware is in place and secure, and
terminals are not bent or broken.
5
Using multimeter, check wire leads and light assembly for continuity, shorts, and opens.
6
Switch terminal S1-41 connects to XDS1-2 through diode D1. Diode D1 ratio of backward
resistance to forward resistance should be not less than 100 to 1.
7
Light assembly terminal 1 connects to terminal 2 internally through lamp.
8
Terminal 3 connects to terminal 2 and lamp only when lamp cover is pushed.
INSTALLATION
1
Using wrench, secure light assembly to cover with nuts and lockwasher.
2
See tags, wire markings and wiring diagram and solder leads.
3
Install lamp and lens cover.
4
Slip box and cover together and align holes.
5
Using screwdriver and wrench, secure box to cover with two screws and self-locking cap nuts.
6
Install remote control assembly in shelter. (See WP0057).
7
Connect power.
END OF TASK
0060 00-3
|