4
Remove the cover.
REPAIR OR REPLACEMENT
1
If captive screws are missing or damaged, install new ones.
NOTE
Installation tool (08524) H7503-8 is required for captive screw installation. Place captive
screw through hole in cover. Turn captive screw into nose threads of installation tool.
Squeeze installation tool handles together firmly. Unscrew installation tool.
INSTALLATION
1
Position rotary switch through hole in cover.
2
Using wrench, secure rotary switch with locking ring, lockwasher, and nut. Positioning tab on
locking ring must fit into hole in cover.
3
Align rotary switch knob setscrew with flat portion of rotary switch shaft.
4
Slip knob onto rotary switch shaft.
5
Using allen wrench, tighten rotary switch knob setscrew.
6
Secure indicator to cover.
7
Place temperature control shaft and positioning tab through holes in cover
8
Using wrench, secure temperature control with lockwasher and nut.
9
Turn temperature control shaft clockwise as far as it will go.
10
Slip knob on temperature control shaft with pointer to the extreme WARMER position.
11
Using allen wrench, tighten temperature control knob setscrew.
12
Slip box and cover together and align holes.
13
Using screwdriver and wrench, secure box to cover with two screws and self-locking cap nuts.
14
Install remote control assembly in shelter. (See WP0057).
15
Connect power.
END OF TASK