TM9 4120-423-14&P
REPAIR OR REPLACEMENT
1
2
See Wire List for wire lengths and terminal information when individual wires are replaced.
TEST AND INSPECTION
1
Using screwdriver and wrench, remove two screws and self-locking cap nuts that retain box to
cover.
2
Pull box away from cover as far as wiring harness will allow.
3
Check connector for general condition, loose, broken, or missing pins. Replace connector if
damaged.
4
Check individual wires for loose solder and terminal lug connectors, cut or frayed insulation, and
cut or broken wires.
5
See wiring diagram and continuity test individual wires. Repair wires with no continuity.
6
Check that gasket is in good condition. Replace if torn, missing, or otherwise damaged.
INSTALLATION
1
See tags and wiring diagram and reconnect leads.
2
Remove tags.
3
Place EMI gasket on connector (J14) end.
4
Slip connector (J14) into box and align holes.
5
Using screwdriver and wrench, secure connector (J14) in proper position to inside of box with
four screws, lockwashers, and nuts.
6
Slip box and cover together and align holes.
7
Using screwdriver and wrench, secure box to cover with two screws and self-locking cap nuts.
8
Install remote control assembly in shelter. See WP0057.
9
Connect power.
END OF TASK