TM9 4120-423-14&P
REPAIR OR REPLACEMENT
Repair is limited to replacement of terminal lug and heat shrinkable insulation tubing. See WP0015 for
general wire repair instructions.
TEST AND INSPECTION
1
Using screwdriver and wrench, remove two screws and self-locking cap nuts that retain box to
cover.
2
Pull box away from cover as far as wiring harness will allow.
3
Check for loose solder connection or terminal lug.
4
Check that diode is connected between switch terminal S1-41 and light terminal XDS1-2.
5
Using multimeter, check diode. Diode (D1) ratio of backward resistance to forward resistance
should not be less than 100 to 1.
INSTALLATION
1
Solder lead to terminal XDS1-2 on light.
2
Connect terminal lug to terminal S1-41 on rotary switch.
3
Slip box and cover together and align holes.
4
Using screwdriver and wrench, secure box to cover with two screws and self locking cap nuts.
5
Install remote control assembly in shelter. See WP0057.
6
Connect power.
END OF TASK
0064 00-3
|