TM9-4120-423-14&P
REPAIR OR REPLACEMENT
NOTE
The coupling half fittings (hose disconnect fittings) used for joining the interconnecting
Refrigerant R-22 metal hoses, contain a poppet valve assembly to prevent Refrigerant R-
22 loss and to keep air from entering the line when hoses are disconnected. The
following instructions apply to both the suction (low pressure) and discharge (high
pressure) couplings.
Male Coupling Half
1
All repairs other than tightening of screw joints will require disassembly and replacement of
some parts. When the half couplings are disassembled for any reason, the O-rings and gaskets
should be replaced.
2
Discharge the Refrigerant R-22 system. (See WP0070).
3
Using wrench, carefully disconnect the suction and discharge condenser to evaporator
Refrigerant R-22 metal hose line connectors from the coupling halves.
4
Using wrench, remove the jam nut.
0092 00-2
|